Measure range : DN15~6000mm
Accuracy : ±1%
Totalizer : 7digit totals
Liquid Types : All kinds of clean liquids
Working Temperature : -30 -160℃
Operating power : 24VDC/220VAC
Protection grade : IP65
Measure range : DN15~6000mm
Accuracy : ±1%
Totalizer : 7digit totals
Liquid Types : All kinds of clean liquids
Working Temperature : -30 -160℃
Operating power : 24VDC/220VAC
Protection grade : IP65
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Introduction:
Modular type ultrasonic flow meters are inferential meters that uses ultrasonic technology to measure the velocity of an acoustically conductive liquid moving through it.
Transit-time measures the time differential between signals sent upstream and downstream. The differential is directly proportional to the velocity of the water. Transit-time meters are best used for measuring the flow of clean liquids and, as a result, are the most popular type of ultrasonic meter.
Feature:
*High Accuracy
Accuracy better than 1%
*Measure Range
Select different model sensors,can achieve DN15-DN6000mm pipe flow measurement
*High Reliability
Adopt low voltage, multi-pulse radiating circuit.Accuracy,Lifetime and Reliability are better.
*High Anti-interference
Adopt double balanced signal differential transmission, receiving circuit,
effective resist the drive,tower, Strong power lines and other source of interference.
*Powerful Memory Function
Automatic memory the cumulative flow of 512 days before, 128 months before, 10 years before. Automatic
memory the power-on and off of 64times before and the flow. Automatic memory the meter working condition of
32days before.
Application:
Chemical industry
City water supply
Waste water treatment
HVAC system
Items | Specifications |
Accuracy | ±1% of reading at rates >0.2 mps |
Repeatability | 0.2% |
Principle | Transmit time |
Velocity | ±32m/s |
Pipe Size | DN15mm-DN6000mm |
Display | LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc. |
Signal Output | 1 way 4-20mA output |
1 way OCT pulse output | |
1 way relay output | |
Signal Input | 3 way 4-20mA input achieve to heat measurement by connecting PT100 platinum resistor |
Other Functions | Automatically record the positive,negative,net totalizer flow rate and heat. Automatically record the time of power-on/off and flow rate of the last 30 times.Replenish by hand or read the datas through Modbus communication protocol. |
Pipe Material | Carbon Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed |
Straight Pipe Section | Upstram: 10D; Downsteam:5D; From the pump:30D (D means outer diameter) |
Liquid Types | All kinds of clean and pure liquids. |
Liquid Temperature | Standard: -30℃ ~ 90℃ ,High-temperature:-30℃ ~ 160℃ |
Liquid Turbidity | Less than 10000ppm, with a little bubble |
Flow Direction | Bi-directional measuring, net flow/heat measuring |
Environment Temperature | Main Unit: -30℃ ~ 80℃ |
Transducer: -30℃ ~ 160℃, Temperature transducer: select on enquiry | |
Environment Humidity | Main Unit: 85% RH |
Transducer: standard is IP65, IP68(optional) | |
Cable | Twisted Pair Line, standard length of 5m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement. RS-485 interface, transmission distance up to 1000m |
Power Supply | DC24V |
Power Consumption | Less than 1.5W |
Communication | MODBUS RTU RS485 |
Contact us for more details about our boilers,solutions and services